For SMS RS485 series servos. Two-byte fields are transmitted with the low byte first.

STS servos (half-duplex TTL) use different address definitions; see STS Memory Table.

1 Servo Communication Protocol

Servos use the FT-SCS proprietary protocol. Factory serial defaults: the SMS baud rate is 115200 on the RS485 bus; configurable baud rate range 38400~1 Mbps, default communication address (station number) 1.

For the full frame format and instruction set, see FT-SCS Protocol.

2 Servo Memory Table Definition

If a function address uses two bytes of data, the low byte is at the leading address and the high byte at the following address

Notes:

  • Initial values and ranges vary by model (shown as – in the table); refer to the data for your model.
  • "Minimum resolution angle" here is the smallest angle the encoder can resolve: the series divides a full turn of 360° into 4096 parts, each 360° ÷ 4096 ≈ 0.0879°, which is the value shown in the Unit column; position and angle-limit registers count in this unit, per your model's data.
  • There are two speed units: 0.732RPM and 0.0146RPM (the latter is 1/50 of the former — it only gives finer command granularity). The smallest physical speed change is still 0.732RPM (one step = 0.0879° every 20 ms): in the fine unit you must write 50 to get one physical step, and writing 1~49 produces no actual speed change.

2.1 Version Information

Address (DEC) Address (HEX) Function Bytes Initial value Access Range Unit Description
0 0x00 Firmware major version 1 – R
1 0x01 Firmware minor version 1 – R
2 0x02 END 1 0 R 0 indicates little-endian storage structure
3 0x03 Servo major version 1 – R
4 0x04 Servo minor version 1 – R

2.2 EEPROM Configuration

Address (DEC) Address (HEX) Function Bytes Initial value Access Range Unit Description
5 0x05 Servo ID 1 1 R/W 0~253 ID Unique main ID on the bus
6 0x06 Baud rate 1 4 R/W 0~7 None 0-7 correspond to baud rates: 1000000(0), 500000(1), 250000(2), 128000(3), 115200(4), 76800(5), 57600(6), 38400(7)
7 0x07 Response return delay 1 0 R/W 0/50~253 2us Maximum settable return delay 254*2=508us; 0 means the minimum return delay; a setting below 50 still defaults to 50 (100us)
8 0x08 Response status level 1 1 R/W 0~1 None 0: no response packet for instructions other than READ and PING; 1: response packet for all instructions
9 0x09 Minimum angle limit 2 0 R/W 0~4094 0.0879° Sets the minimum running angle limit; the value must be smaller than the maximum angle limit; minimum angle limit = maximum angle limit = 0 enters multi-turn absolute position control mode
11 0x0B Maximum angle limit 2 4095 R/W 0~4095 0.0879° Sets the maximum running angle limit; the value must be larger than the minimum angle limit; minimum angle limit = maximum angle limit = 0 enters multi-turn absolute position control mode
13 0x0D Maximum temperature limit 1 70 R/W 0~100 °C Temperature threshold of the overheat protection
14 0x0E Maximum input voltage 1 – R/W 0~254 0.1V Voltage threshold of the over-voltage protection
15 0x0F Minimum input voltage 1 40 R/W 0~254 0.1V Voltage threshold of the under-voltage protection (the default suits low-voltage models; raise it for higher-voltage models)
16 0x10 Maximum torque 2 1000 R/W 0~1000 0.1% Written to address 48 (torque limit) at power-on
18 0x12 Phase 1 – R/W 0~254 None Special function byte; do not modify unless specifically required
19 0x13 Unload condition 1 – R/W 0~254 None Set bit to 1 to enable the corresponding protection, set bit to 0 to disable it; bit definitions in 3.3 Unload Condition
20 0x14 LED alarm condition 1 – R/W 0~254 None Set bit to 1 to enable the flashing LED alarm, set bit to 0 to disable the flashing LED alarm; bit definitions in 3.4 LED Alarm Condition
21 0x15 Position loop P (proportional) coefficient 1 – R/W 0~254 None Proportional coefficient controlling the motor (1/4)
22 0x16 Position loop D (derivative) coefficient 1 – R/W 0~254 None Derivative coefficient controlling the motor (1/8)
23 0x17 Position loop I (integral) coefficient 1 0 R/W 0~254 None Integral coefficient controlling the motor
24 0x18 Minimum startup torque 1 – R/W 0~254 0.1% Sets the minimum output startup torque of the servo
25 0x19 Integral limit 1 0 R/W 0~254 None Maximum integral = limit × 4; 0 disables the integral limit; effective in position mode 0 and mode 4 (mode 4 is a custom build, only on special models)
26 0x1A Positive deadband 1 1 R/W 0~16 0.0879° The minimum unit is one minimum resolution angle
27 0x1B Negative deadband 1 1 R/W 0~16 0.0879° The minimum unit is one minimum resolution angle
28 0x1C Protection current 2 511 R/W 0~2047 6.5mA The maximum settable current is 500 * 6.5mA = 3250mA (a suggested upper limit; follow your actual model)
30 0x1E Angle resolution 1 1 R/W 1~128 None Magnification factor of the sensor's minimum resolution angle: set to K, one count = K × 0.0879° and the full 0~4095 range covers K turns; a larger K means more turns but a coarser step
31 0x1F Position offset 2 0 R/W 0~8191 0.0879° 0~2047 represents 0~2047; 2048~4095 represents 0~-2047; 4096~6143 represents 2048~4095; 6144~8191 represents -2048~-4095 (that is, an offset of -4095~4095)
33 0x21 Operating mode 1 0 R/W 0~3 None 0: position servo mode; 1: constant-speed motor mode; 2: PWM open-loop speed-control mode; 3: step mode
34 0x22 Holding torque 1 20 R/W 0~254 1% Torque output after entering overload protection; for example 20 means 20% of the maximum torque
35 0x23 Protection time 1 200 R/W 0~254 10ms Duration for which the load output exceeds the overload torque and is held; for example 200 means 2 seconds, maximum 2.54 seconds
36 0x24 Overload torque 1 80 R/W 0~254 1% Maximum torque threshold that starts the overload protection timer; for example 80 means 80% of the maximum torque
37 0x25 Velocity loop P (proportional) coefficient 1 – R/W 0~254 None Speed-loop proportional coefficient in constant-speed motor mode (mode 1)
38 0x26 Overcurrent protection time 1 200 R/W 0~254 10ms Maximum settable 254 * 10ms = 2540ms
39 0x27 Velocity loop I (integral) coefficient 1 – R/W 0~254 None Speed-loop integral coefficient in constant-speed motor mode (mode 1)

2.3 SRAM Control

Address (DEC) Address (HEX) Function Bytes Initial value Access Range Unit Description
40 0x28 Torque switch 1 0 R/W 0~2 None Write 0: torque output off; write 1: torque output on; write 2: damping output (torque limit (48) controls the damping force); write 128: calibrate the current position to 2048
41 0x29 Acceleration 1 0 R/W 0~254 8.79°/s² Run acceleration/deceleration of the servo; 0 means maximum acceleration
42 0x2A Goal position 2 0 R/W -32767~32767 0.0879° Absolute position control; the maximum corresponds to the maximum effective angle; BIT15 is the direction bit; ±32767 is the conceptual range — what you actually write is the magnitude (0~32767), and set BIT15 to 1 for the reverse direction
44 0x2C PWM open-loop speed 2 1000 R/W -1000~1000 0.1% Effective in PWM open-loop speed mode, where it is the PWM duty cycle; write the magnitude (0~1000) and set BIT10 to 1 for the reverse direction
46 0x2E Running speed 2 Factory default maximum speed R/W -32767~32767 0.732RPM/0.0146RPM Controls the maximum running speed of the motor; BIT15 is the direction bit; 0 means the maximum speed by default and can be set to mean stop via the phase setting; the unit follows the phase setting, either 0.732RPM or 0.0146RPM (decided by phase BIT2); 0.0146RPM simply splits the 0.732RPM physical step into 50 command levels, so the physical resolution stays 0.732RPM
48 0x30 Torque limit 2 Maximum torque (16), default 1000 R/W 0~1000 0.1% This value can be modified in software to control the stall torque output
50~54 0x32~0x36 Undefined 5
55 0x37 Lock flag 1 1 R/W 0~1 None Write 0 to close the write lock: values written to EEPROM addresses persist after power-off; write 1 to open the write lock: values written to EEPROM addresses do not persist

2.4 SRAM Feedback

Address (DEC) Address (HEX) Function Bytes Initial value Access Range Unit Description
56 0x38 Present position 2 – R – 0.0879° Absolute position feedback of the servo; BIT15 is the direction bit; in step mode 3 it returns the step difference between the present position and the goal position, with BIT15 as the direction bit
58 0x3A Present speed 2 – R – 0.732RPM/0.0146RPM Rotational speed of the motor; the unit follows the phase setting; BIT15 is the direction bit
60 0x3C Present load 2 – R – 0.1% Duty cycle of the output driving the motor; BIT10 is the direction bit
62 0x3E Present voltage 1 – R – 0.1V Current working voltage of the servo
63 0x3F Present temperature 1 – R – °C Current internal working temperature of the servo
64 0x40 Async write flag 1 0 R – None Flag used with the async write instruction: set to 1 as soon as the async write instruction (0x04, unicast or broadcast) is accepted, cleared to 0 as soon as the execution instruction (0x05) is accepted; a direct write (0x03) does not change it; it is a RAM bit and clears at power-off.
65 0x41 Servo status 1 0 R – None A bit set to 1 indicates the corresponding error
66 0x42 Moving flag 1 0 R – None 1 while the servo is moving, 0 when the target is reached and the servo stops; stays 0 when no new goal position is written
67 0x43 Goal position 2 0 R – 0.0879° Current goal position
69 0x45 Present current 2 – R – 6.5mA Motor phase current feedback
71 0x47 Undefined 2 – R – –

2.5 Factory Parameters

Address (DEC) Address (HEX) Function Bytes Initial value Access Range Unit Description
80 0x50 Moving speed threshold 1 – R – –
81 0x51 DTs(ms) 1 – R – –
82 0x52 Speed unit coefficient 1 – R – –
83 0x53 Hts(ns) 1 – R – – 20.83ns, valid for SMS servo firmware >= 2.54, other versions keep 0
84 0x54 Maximum speed limit 1 – R – – Unit 0.732rpm
85 0x55 Acceleration limit 1 – R – –
86 0x56 Acceleration multiplier 1 – R – – The acceleration multiplier takes effect when acceleration is 0; when both the multiplier and the acceleration are 0 the servo responds at the highest speed

3 Special Byte Explanation

3.1 Servo Phase

Bit (weight): Description

  • BIT0 (1): Drive direction phase; (0) forward, (1) reverse
  • BIT1 (2): Driver bridge mode; (0) brushless, (1) brushed, takes effect after restart
  • BIT2 (4): Speed unit, (0) 0.732RPM, (1) 0.0146RPM
  • BIT3 (8): Speed mode; (0) speed 0 means stop, (1) speed 0 means maximum speed
  • BIT4 (16): Angle feedback mode, (0) single-turn angle feedback, (1) full-angle feedback
  • BIT5 (32): Voltage sampling, (0) 1.5K low-voltage sampling, (1) 1K high-voltage sampling
  • BIT6 (64): PWM frequency, (0) 24kHz, (1) 16kHz
  • BIT7 (128): Position feedback direction phase, (0) forward, (1) reverse

Note

If multiple bits are set at the same time, the phase value is the sum of the bit values. Example: with an original phase value of 0, if the servo runs in reverse, the phase value is 128+1=129;

3.2 Servo Status

Servo status: 0 means normal, 1 means abnormal

Bit (weight): Description

  • BIT0 (1): Voltage status
  • BIT1 (2): Magnetic encoder status
  • BIT2 (4): Temperature status
  • BIT3 (8): Current status
  • BIT4 (16): ----
  • BIT5 (32): Load status
  • BIT6 (64): ----
  • BIT7 (128): ----

Note

If multiple statuses occur at the same time, the status value is the sum of the bit values. Example: over-voltage/under-voltage together with servo overheating gives a status value of 4+1=5;

3.3 Unload Condition

Unload condition: 0 means off, 1 means on

Bit (weight): Description

  • BIT0 (1): Voltage protection
  • BIT1 (2): Magnetic encoder protection
  • BIT2 (4): Overheat protection
  • BIT3 (8): Overcurrent protection
  • BIT4 (16): ----
  • BIT5 (32): Load overload
  • BIT6 (64): ----
  • BIT7 (128): ----

Note

If multiple bits are set at the same time, the unload condition value is the sum of the bit values. Example: with voltage protection and overheat protection enabled together, the unload condition value is 4+1=5;

3.4 LED Alarm Condition

LED alarm condition: 0 means off, 1 means on

Bit (weight): Description

  • BIT0 (1): Voltage alarm
  • BIT1 (2): Magnetic encoder alarm
  • BIT2 (4): Overheat alarm
  • BIT3 (8): Overcurrent alarm
  • BIT4 (16): ----
  • BIT5 (32): Load overload alarm
  • BIT6 (64): ----
  • BIT7 (128): ----

Note

If multiple bits are set at the same time, the LED alarm condition value is the sum of the bit values. Example: with the voltage alarm and the overheat alarm enabled together, the alarm condition value is 4+1=5;

Do not reuse addresses across families

Other series may use the same address with a different meaning (for example, HLS addresses 44–45 are the goal current, while in this table they are PWM open-loop speed). Return to Bus Protocol and select the matching memory table.

4 Common Workflows

Once the connection is up, day-to-day work on the servo comes down to reading and writing a handful of registers. This section collects the common ones by task; how to build the instruction frames is out of scope here — see FT-SCS Protocol. All numbers below refer to the addresses in this table.

4.0 Before You Start

  • EEPROM area (2.2, 5~39): write 55 Lock flag = 0 before changing anything, and write 1 back afterwards, otherwise the value is not saved. Measured: with the lock flag at 1 a write is still accepted and takes effect immediately, but it does not survive power-off; enabling (40 Torque switch) does not affect saving.
  • SRAM area (2.3, 40~55): write directly, effective immediately, lost at power-off — good for trial writes; 55 Lock flag itself lives here, so writing it needs no unlock.
  • 56~71 in 2.4 and 80~86 in 2.5 are read-only; reading them does not change the servo state.
  • This series runs on an RS-485 bus: the two wires A/B must not be swapped and the transceiver module switches the direction; the factory baud rate is 115200 (gear 4), unlike the 1 Mbps of the STS / HLS series, so check your host baud rate first.
  • Position registers in this series count in "minimum resolution angle": by default (angle resolution in 30 = 1) a full turn is 4096 counts and each count is 0.0879° (360° ÷ 4096) — that is the "count" used below; with 30 set to K one count becomes K × 0.0879°.

4.1 Getting the Servo Moving

Goal: turn the output shaft through a small angle for the first time.

Step Action Register Value / example
1 Read the present position, mask BIT15 (direction), call it P 56 Present position read-only, e.g. 2048
2 Drop the torque limit to 30% 48 Torque limit 300 (power-on default comes from 16 = 1000)
3 Set the running speed 46 Running speed 100 (100 × 0.732 RPM ≈ 73 RPM)
4 Turn the torque output on (can be skipped) 40 Torque switch 1
5 Write the goal position 42 Goal position P + 200 (about 17.6°)

Turning by angle

42 Goal position takes an absolute position, so "turn 90°" first needs a reference point. One count is 0.0879°, and 90° is exactly 1024 counts.

Desired result How to work it out Worked example
Turn another 90° from the present position (recommended) read 56 Present position as P (mask BIT15), goal = P ± (90° ÷ 0.0879°) P ± 1024
Turn 90° from the start of the travel goal = 90° ÷ 0.0879° 1024
  • Try P + 1024 first; if it turns the wrong way, use P − 1024. Which side adds depends on how the horn is mounted.
  • If the result is negative, write its absolute value and set BIT15 (direction bit) in 42 Goal position.
  • The goal must stay within 9 Minimum angle limit / 11 Maximum angle limit (see 4.3).

Notes:

  • 48 Torque limit is in SRAM: effective immediately, lost at power-off, and re-loaded from 16 Maximum torque at power-on, so 48 is the easy one to change for a trial; use 16 only when the value must persist (EEPROM, so unlock first).
  • The unit of 46 Running speed is decided by BIT2 of 18 Phase (0.732 RPM / 0.0146 RPM); what 0 means is decided by BIT3: with BIT3=1, 0 means the highest speed; with BIT3=0, 0 means stop (bit definitions in 3.1 Servo Phase).
  • Besides 0/1, 40 Torque switch also takes 2 (damping output, with the damping force set by 48) and 128 (calibrate the present position to 2048, see 4.2); for the first trial, 1 is all you need.
  • Writing 42 Goal position directly sets 40 Torque switch to 1 automatically, so step 4 can be skipped.
  • With several servos on one RS-485 bus, 7 Response return delay can stagger their reply slots (unit 2 μs; 0 or anything below 50 gives 100 μs).

Check: while moving, 66 Moving flag is 1 and returns to 0 on arrival; 56 Present position (mask BIT15) should then equal the magnitude of the goal (or the boundary value if clamped by the travel range).

4.2 Midpoint Calibration

Goal: make goal position 2048 correspond to the pose in which the horn is mounted square. The magnetic encoder zero is fixed to the factory shaft angle, and mounting a horn usually introduces an offset — this step puts the zero back where it belongs.

Register: 40 Torque switch (write 128).

Steps:

  • First turn the output shaft by hand to the pose in which the horn should sit square (you can take the horn off, calibrate, then refit it).
  • Write 40 Torque switch = 128: the servo then treats the present position as 2048 (half a turn).

Notes:

  • The shaft should be unloaded and still during calibration; every execution turns "wherever it is now" into 2048, so repeating it accumulates offset.
  • After calibration the whole 0~4095 zero point shifts: position readings taken before are invalid. If the travel limits are still the factory 0 / 4095 (full turn), they still cover a full turn after the shift and need no change; if you set a custom range, the values in 9 Minimum angle limit / 11 Maximum angle limit now refer to the shifted physical angle and must be set again against the new zero (see 4.3).
  • After a power cycle, read 56 Present position again to confirm the calibration held; 31 Position offset is computed by the firmware during calibration and written for you (EEPROM, so it persists) — no need to edit it by hand.

Check: after writing, 56 Present position should read 2048; then write 42 Goal position = 2048 and the shaft should not move at all.

4.3 Setting the Travel Range

Goal: limit how far the output shaft may turn.

Registers: 9 Minimum angle limit and 11 Maximum angle limit, in minimum resolution angle (0.0879°); both are in the EEPROM area, so unlock 55 Lock flag before writing.

Steps:

  • Convert the boundaries you want into counts (angle ÷ 0.0879°, see "Turning by angle" in 4.1).
  • Write 9 and 11; 9 must be smaller than 11; write 55 Lock flag = 0 first and set it back to 1 afterwards.

Notes:

  • Factory defaults are 9 = 0 and 11 = 4095, i.e. a full turn.
  • Setting both 9 and 11 to 0 enters multi-turn absolute position control, which is no longer bound to a single turn — an advanced use; to return to normal mode, write both limits again.
  • The limits only constrain goal position commands; an external force can still push the shaft past them.

Check: first set 11 Maximum angle limit to 2048 (EEPROM, so unlock first), then write 42 Goal position = 3000; the shaft should stop at 2048 counts and go no further.

4.4 Changing the ID

Goal: change the bus address of the servo; do this before building a multi-servo bus.

Registers: 5 Servo ID, 55 Lock flag; for several servos the timing can be staggered with 7 Response return delay.

Pitfalls:

  • Only write it when this is the only servo on the bus; with several servos, power them one at a time.
  • Writing through the broadcast address changes every servo on the bus at once.
  • ID range 0~253; never duplicate an ID on the same bus.
  • After a successful write the servo answers on the new ID at once and no longer answers on the old one; the re-lock and any PING afterwards must use the new ID in the ID byte (no need to reopen the port) — sending with the old ID only times out.

Steps: confirm this is the only servo on the bus → write 55 = 0 → write 5 = new ID → using the new ID write 55 = 1.

Check: a PING with the new ID (or a read of 5) should answer, and the old ID should not. For the broadcast method see FT-SCS Protocol.

4.5 Changing the Baud Rate

Goal: change the communication baud rate to match the host. Factory default is 115200 (gear 4) — note that this differs from the 1 Mbps of STS / HLS.

Registers: 6 Baud rate, 55 Lock flag.

Pitfalls:

  • What you write is the gear number 0~7, not the baud rate itself (0=1000000, 1=500000, 2=250000, 3=128000, 4=115200, 5=76800, 6=57600, 7=38400).
  • The current connection drops the moment the write succeeds: the servo switches to the new gear at once and stops answering on the old rate, so reconnect at the new rate (change the rate and reopen the port in your serial tool, or reinitialise the UART on the host) before sending anything else — the re-lock included; with a wrong gear you can only retry gear by gear or restore the factory default.
  • The host and every servo on the bus must use the same gear; a mixed bus does not communicate, and the RS-485 transceiver module itself must support the rate as well.

Steps: unlock as described in 4.0 Before You Start → write 6 = new gear (the connection drops here) → reconnect at the new rate → write 55 = 1.

Check: reconnect at the new rate and send a PING; an answer is all you need. For lost connections see Troubleshooting.

4.6 Configuring Protection

Goal: set temperature, voltage, current and overload protection so a stall does not damage the servo.

Registers:

Role Register Notes
Temperature threshold 13 Maximum temperature limit °C, default 70; crossing it sets BIT2 of 65
Voltage threshold 14 Maximum input voltage / 15 Minimum input voltage 0.1 V; 15 defaults to 40, i.e. 4.0 V (set for low-voltage models; raise it for higher-voltage models)
Current threshold 28 Protection current / 38 Overcurrent protection time 28 is 6.5 mA per count (default 511 ≈ 3.3 A), 38 is 10 ms per count (default 200 = 2 s)
Whether to unload the output 19 Unload condition bit-wise enable of voltage, magnetic encoder, overheat, overcurrent and load, with bit definitions in 3.3 Unload Condition
Whether to flash the LED 20 LED alarm condition a separate channel; it flashes only on models with an LED, bit definitions in 3.4 LED Alarm Condition
Overload torque drop 36 Overload torque / 35 Protection time / 34 Holding torque once the load exceeds the torque in 36 (80 = 80%) for the time in 35 (200 = 2 s), the output torque drops to the holding torque in 34 (20 = 20%)

All of the above are in the EEPROM area (2.2), so unlock 55 Lock flag before writing.

Key points:

  • Temperature, voltage and current protection need both conditions to fire: the matching bit of 19 Unload condition set to 1 (that item enabled) plus the measured value crossing the threshold in 13~15 or 28 → that protection acts (unloads the output); with the bit at 0 it never acts.
  • Overload is a separate chain: once the load exceeds 36 Overload torque for 35 Protection time, the output torque drops to 34 Holding torque; whether the output is also unloaded is decided by BIT5 (load overload) of 19.
  • 65 Servo status reflects the detection layer: the bit is set as soon as the threshold is crossed, whether or not 19 is enabled; 20 LED alarm condition is another independent channel — an alarm on 20 never substitutes for unloading on 19.
  • BIT1 (magnetic encoder protection) of 19 has no threshold register: it fires when the sensor itself reports an error and does not depend on the values in 13~15 or 28.
  • 13~15 and 28 are thresholds, not switches: writing 0 to one of them does not disable that protection.

Check: confirm the matching bit of 19 is set to 1, then cross a threshold on purpose (or stall the servo) and read 65: the matching bit turns 1 and the output follows the protection; both return to 0 once the condition clears.

4.7 Reading Status to Troubleshoot

Goal: locate a problem with read-only registers when the servo misbehaves.

Registers: 56 Present position, 58 Present speed, 60 Present load, 62 Present voltage, 63 Present temperature, 65 Servo status, 66 Moving flag, 67 Goal position, 69 Present current; all read-only, reading them at will does not affect the servo.

Order to check:

  • Read 65 Servo status: if it is not 0, decode it bit by bit with 3.2 Servo Status (1 = voltage, 2 = magnetic encoder, 4 = temperature, 8 = current, 32 = load).
  • Read 62 Present voltage / 63 Present temperature: compare them with the thresholds set in 13~15.
  • Read 69 Present current: multiply by 6.5 mA and see how close it is to the threshold in 28 Protection current (this table does not specify a direction bit).
  • Read 60 Present load: mask BIT10 (direction bit) first, then scale 0~1000; a value close to 100% for a long time means a stall or too little torque.
  • Read 56 / 67 / 66: compare the present position with the goal position and check the moving flag to see whether the command was executed; mask BIT15 (direction) in both 56 and 58.
  • The bus itself: when several servos do not answer, first check that A/B are not swapped and that the host and the servos use the same baud rate gear, then stagger the reply slots with 7 Response return delay.

Source Definition